carte(s) raid scsi [VDS/ECH] - Hardware - Achats & Ventes
Marsh Posté le 02-02-2004 à 19:29:29
Pour la PLR:
CONTROLLER SPECIFICATIONS:
? RISC Processor........................Intel i960RP
? Speed.................................33MHz
? PCI...................................2.1
? I2O...................................Compliant
? EDO RAM...............................4MB
? Flash.................................1MB
PHYSICAL SPECIFICATIONS:
? PCI card..............................Half length
? Power Requirements....................+5.0v (+-5%) 3.5 A (max); 17.5 watts
? Temperature...........................0 to 55?C
? MTBF..................................387,000 hrs.
? Certification.........................FCC Class B, UL, CE, Windows NT, Netware
SCSI SPECIFICATIONS:
? Supports SCSI1, SCSI2, Ultra SCSI, and Ultra2 SCSI devices
? Full support for Low Voltage Differential (LVD) devices
? Up to 80MB/sec burst data rate o Automatic SCSI bus termination
? Disconnect/Reconnecto 64 concurrent host commands
? 256 tagged commands per controllero Automatic sector remapping
? Ultra2 SCSI (LVD) cable length up to 25 meters for two devices or
? 12 meters for 15 deviceso One Wide Ultra2 SCSI LVD channel
? Up to 15 devices per channel
? Up to 2.70TB per system (depending on configuration; multiple
controllers and SCSI channels on system board)
RAID FAULT TOLERANT AND FLEXIBILITY FEATURES:
? RAID levels 0, 1, 0+1, 3, 5, 10, 30, 50, JBODo Transparent disk drive rebuild
? Online RAID expansion (M.O.R.E.2)o Up to eight controllers per system (NT)
? Logical drive size of 2TB, 32 logical drives per controller
? Immediate RAID availability; background initialization
? Variable stripe size per controllero Variable cache line size per controller
? Up to eight non-disk devices per controllero Drive roaming during power off
? SAF-TE enclosure managemento StorageWorks compatibleo Automatic error recovery
? Write-through or write-back cache support/logical device \Automatic detection of failed driveso Automatic rebuild of hot spare drive \Hot drive swapping supporto Support for SMART capable drives
? Configuration data stored on disk and NVRAMo PCI Hot Plug (NT and NetWare)
? RAID MANAGEMENTo Global Array Manager - Client server GUI interface
? Create, manage, expand and monitor programs
? Error statistics and performance informationo Workstation Array Manager
? BIOS configuration utility - RAID EzAssistSYSTEM DRIVER SUPPORT
? Windows NT Server 4.0 and Enterprise Edition, Windows NT Workstation 4.0
? NetWare 4.11 & above, 5.x and SMPo SCO UnixWare 2.1, 7.0, UNIX OSR 5.x
? DOS 5.x, 6.x and aboveo Linux 2.2o DOS 5.x, 6.x and aboveAcceleRAID 150
Marsh Posté le 02-02-2004 à 19:34:44
Pour les PG:
DAC960PG 1/2/3 Wide Ultra SCSI-3 Channels
33MHz Intel i960RP RISC Processor
16Mo ECC EDO Memory
Marsh Posté le 03-02-2004 à 22:06:24
mets les prix :
1) c'est chart compliant et çà t'évite modosoucis
2) tes cartes sont de belles cartes
lances toi mets le price
Marsh Posté le 04-02-2004 à 07:51:03
Bah je dis plus haut "echange"...
Allez je mets des prices:
200? pour 1 PG
150? pour 1 PLR
Marsh Posté le 02-02-2004 à 19:28:43
Voila donc j'ai:
1 Mylex DAC960PLR
2 Mylex DAC960PG
Dans l'ordre:
Je suis ouvert au échange en priorité:
Disques dur - carte serial ATA - Appareil photo numérique......Et d'autres ....
Il ne vous reste donc plus qu'à proposer ce que vous avez.
Pour les decriptions, google est votre amis
La PLR est U2W(4Mo) et les PG en U160 (16Mo).
VENTE POSSIBLE